Jeti USA Central Box 220 Power Distribution Unit with Magnetic Switch

Download the Instruction Manual Here
Download the Menu Diagram Here
Includes: (1) Jeti Central Box, (1) Magnetic Switch, (1) Magnetic Key

  • Control Management with Configurable Servo Output
  • Power Distribution with Two Independent Inputs
  • Heavy Duty Aluminum Case for Extra Cooling and Protection
  • Firmware Updatable via Jeti USB Adapter and Jeti Studio
  • Wirelessly Programmable Using DC/DS Tx Device Explorer
  • Independent Receiver Signal Inputs (R1, R2, E1/R3)
  • Up to 15x Standard PWM and Ditex Telemetry Servo Outputs
  • Up to 3x Telemetry Sensors Inputs (E1/R3, E2/15, E3/14)
  • Input for Included Magnetic or Optional Wireless Switch
  • Input Voltage: 4V
  • 8.4V
  • Output Current: 2x 20A Continues/90A Peak
  • Dimensions/Weight: 65mm x 42mm x 18mm/59g

The Central Box 220 is a switchboard designed for the complete management of servos in a model with an emphasis on safety. The Central Box 220 has a unique design that provides overload protection for up to 11 Standard (up to 415 oz/in, 30 kg/cm) and 4 Ultra Torque (up to 830 oz/in, 60 kg/cm) servos. The Central Box 220 features true Battery Redundancy, Ditex Servo Telemetry, Jeti EX Telemetry, and up to three receiver inputs (2x 2.4GHz and 1x 900MHz) with serial (PPM, EX Bus) output for complete Power & RF Signal Redundancy.

With Jeti Duplex 2.4GHz DC/DS transmitters, the full potential of the Central Box can be used, such as easy way to wirelessly configure the Servo Outputs, Ditex Servo & EX Telemetry, Fail-Safe Setting or Function Assignment.

Power Supply
The power batteries are connected to the Central Box using MPX connectors. The Central Box allows two batteries to be connected. During use, the power is actually supplied from the battery with the higher voltage. If the voltage is the same, the power can be used from both batteries at the same time. When the voltage of the batteries is different, the power is not shared and each pack is isolated from the other. This allows you to use batteries of different capacity, number of cells and chemistry type. If the power for the Central Box is provided only from one battery, it can be connected via battery (BATT 1) Input.

Magnetic Switch
The magnetic switch is used to turn the Central Box ON/OFF and is connected to a separate slot labeled "SW". To turn on the Central Box using the magnetic switch it is necessary to hold the supplied magnet (key) to the target so that the key and the target on the magnetic switch are properly oriented.

Wireless Switch R3/RSW
State-of-the-art device that sets Jeti as a leading designer and manufacturer of radio control systems. Wireless power switch is fully integrated into the 2.4GHz radio system. For first time your receiver can be turned ON/OFF with simple flipping of the switch wirelessly from the Jeti DC/DS transmitters.

Fail-Safe Setting
Switches ON/OFF of the Fail-Safe function. If the Fail-Safe function is deactivated, there is no signal generated in any Central Box outputs at the signal loss. If you activate the Fail Safe function, you can also select how the Central Box responds at signal loss for each of the individual outputs.

Servo Mapping

  • Servo No. - Assigning outputs of the transmitter to the Central Box outputs.
  • Group - Assigning specific output to the group of output impulses that will be generated from the receiver in the same time.

Ditex Servo Telemetry
The Ditex telemetry servos offer groundbreaking design features combined with incredible reliability. Advanced radio control telemetry systems such as Jeti Duplex are capable of providing real-time information including complete telemetry data (Torque, Min/Max Current, Voltage, Angle, Telemetry Alarms) and full system integration.

Duplex Telemetry

  • Temperature - Temperature of the Central Box
  • Voltage - Voltage (V) of Individual Outputs of the Central Box
  • Current - Current (A) Drawn from the Battery
  • Capacity - Capacity (mAh) Taken from the Batteries